Removal procedure
1. Disconnect the negative battery cable.
2. Disconnect the ECM connectors from the ECM.
3. Remove the ECM bracket mounting nuts.
4. Remove the ECM along with the bracket from the battery tray.
5. Release the ECM-to-bracket clips and separate the ECM from the bracket.
Installation procedure
1. Install the ECM to the bracket.
2. Install the ECM with the bracket to the battery tray.
Tighten
Tighten the ECM bracket mounting nuts to 15 Nm (11 lb-ft).
3. Connect the ECM connectors to the ECM.
4. Connect the negative battery cable.
Attention! If the ECM was replaced, reprogram the ECM.