Removal procedure
1. Disconnect the negative battery cable.
2. Release the connector lock and pull out the sensor cable connector.
3. Remove the sensor with the key.
4. Dispose of the O-ring.
Installation procedure
1. Install a new O-ring on the sensor.
2. Install pressure sensor.
Tighten
Tighten pressure sensor to 7 Nm (62 lb-in).
3. Connect the cable connector.
4. Connect the negative battery cable.