Removal procedure
1. Disconnect the negative battery cable.
2. Remove glove box. See section 9E, "Instruments/driver information system".
3. Remove the top cover of the footwell. See section 9E, "Instruments/driver information system".
4. Remove the motor and seal from the heater/air distributor housing by carefully pulling the motor straight down and out.
5. Unscrew the screws securing the electric motor to the heater/air distributor housing.
Installation procedure
1. Install the motor, seal and shock absorber mounts on the heater/air distributor housing. Hold the electric fan in place.
2. Tighten the screws that secure the electric fan to the heater/air distributor body.
Tighten
Tighten the screws that secure the fan to the heater/air distributor housing assembly to 6 Nm (53 lb-in).
3. Connect the fan electrical connector.
4. Connect the negative battery cable.
5. Verify that the electric fan is working properly.
6. Install the upper footwell cover. See section 9E, "Instruments/driver information system".
7. Install the glove box. See section 9E, "Instruments/driver information system".