Preliminary Operations
Drain the cooling system.
Remove the air filter housing.
Removal and installation
1. (Modifications) Disconnect the low coolant sensor connector.
2. Remove the bolts (1) expansion tank attachment. Tightening torque 10 Nm.
3. Loosen the nuts (2) expansion tank attachment. Tightening torque 10 Nm.
4. Disconnect from a tank hoses and remove a tank.
5. Installation is carried out in the reverse order.