Withdrawal procedure
1. Disconnect the cable from the negative battery terminal.
2. Remove floor console. See Section 9G, Interior lining.
3. Disconnect electrical wiring connectors.
4. Remove fixing clamp (1) shift control cable and shift control cable (2) from the shift control lever assembly.
5. Loosen the gear lever assembly retaining nuts and remove the shift control assembly.
Installation order
1. Install the gear lever assembly retaining nuts.
Tighten
Tighten the fixing nuts of the gear lever assembly to 8 Nm (71 lb-in).
2. Install cable (2) on the shift control lever assembly and secure the cable with a new retaining clip (1) shift control cable.
3. Adjust cable. See «Shift cable adjustment» in this section.
4. Connect electrical wiring connectors.
5. Install floor console. See Section 9G, Interior lining.
6. Connect the wire to the negative terminal of the battery.